The PW type pump is a horizontal, single-stage, single suction cantilever centrifugal sewage pump, while the PWL type pump is a vertical single-stage, single suction centrifugal sewage pump. Suitable for transporting liquids with fibers or other suspended solids below 80 ℃ for urban and industrial enterprises to discharge sewage and feces. PW and PWL pumps are not suitable for transporting acidic, alkaline, and other chemical mixtures containing a lot of salt that can cause metal corrosion. The PWF type pump is a horizontal single-stage single suction cantilever acid resistant sewage pump, suitable for discharging acidic, alkaline or other corrosive sewage. It can be used for transporting chemical slurry in the chemical industry, with liquid temperature below 80 ℃. Model Meaning Example: 6PWL Example: 50PWF1.6- Pump Discharge Diameter (mm) 1.50- Pump Discharge Diameter (mm) 2- P - Impurity Pump 2- Impurity Pump 3- W - Sewage 3- W - Sewage 4- L - Vertical 4- F - Corrosion Resistance

Installation & Maintenance Notes
- 1 Before first start-up, check the motor rotation direction and make sure it matches the pump direction.
- 2 Every time before starting, turn the shaft by hand through one full revolution — it must turn freely without jamming or rubbing.
- 3 Keep a 2–3 mm clearance at the coupling.
- 4 Grease the bearings regularly every shift.
Related Products
Hydraulic Sand Pump
Selection of hydraulic sediment pump: 1. Select the pump type according to the actual flow rate, head, and delivery distance required for the operating conditions, and calculate the required hydraulic power based on the motor power of the pump type; 2. The hydraulic power calculated based on the selected pump type matches the hydraulic oil station that can meet the hydraulic power requirements; 3. Calculate the actual output power of the excavator hydraulic system and select the appropriate pump type; 4. Customized modifications can also be made according to specific customer requirements (such as screw type, rake suction type, bucket wheel type). Drive mode: hydraulic drive Material used: high chromium wear-resistant alloy Additional mixing: dual agitator type, single twist cage
NL80-300-11 Vertical Slurry Pump
Attention: 1. Before starting up, test the motor rotation direction, which should be consistent with the pump rotation direction before starting up. 2. Rotate the pump manually for one week before each start-up, and only start when there is no jamming or grinding. 3. Leave a gap of 2-3 millimeters between the couplings. 4. Add butter on time for each shift. This pump has the advantages of long service life, simple structure, and reliable performance. The sealing type is oil seal type, and the overcurrent components have two types: ordinary wear-resistant and high wear-resistant. Note: Two leaves with a particle size of 70 millimeters.
6PS-30 Diesel Engine Horizontal Pump
3PNL-22 Vertical Slurry Pump
Attention: 1. Before starting up, test the motor rotation direction, which should be consistent with the pump rotation direction before starting up. 2. Rotate the pump manually for one week before each start-up, and only start when there is no jamming or grinding. 3. Leave a gap of 2-3 millimeters between the couplings. 4. Add butter on time for each shift. This pump has the advantages of long service life, simple structure, and reliable performance. The sealing type is oil seal type, and the overcurrent components have two types: ordinary wear-resistant and high wear-resistant. Note: Two leaves with a particle size of 70 millimeters.